MSA ACCOUNTABILITY SYSTEM
Accountability is key to every firefighter's safety on a fire scene. You simply can't afford not to have the very best telemetry technology available. MSA's Accountability System technology combines software with a high-performance radio module and the field-proven technology of MSA's ICM TxR Integrated PASS. Add the Accountability System to MSA's FireHawk M7 Air Mask, and you'll be wearing the best integrated SCBA accountability system available. Each MSA base station can monitor up to 50 firefighters; multiple base stations can be used with a single computer. The Accountability System transmits firefighter name, team assignment, cylinder pressure, service-time remaining, PASS alarms (motion or manual), thermal alarms, battery status,radio connectivity, and evacuation acknowledgement to incident command.
MSA CLEARCOMMAND COMMUNICATIONS
MSA's ClearCommand Communication System is designed specifically to meet firefighters' modern communication needs. The ClearCommand System is available in two versions: amplifier, and amplifier with radio interface, allowing firefighting teams to be properly fitted for the job at hand. Innovative design helps to reduce expenses via its shared-use amplifier, reducing individual issue equipment. ClearCommand Systems feature an internally-mounted microphone coupled with a large diameter (2") amplifier speaker for optimal clarity and volume. Using a patented circuit design, the system delivers over twice the volume of a facepiece alone. Mounted in an out- of-the -way position, the ClearCommand System does not block vision or mechanical communication. The Ultra Elite Facepiece's mechanical voicemitter still functions fully with the system installed. The radio interface version features the same amplifier as the amp -only version, combined with an ear-speaker for incoming radio messages, and a push-to-talk assembly for interface with over 100 radio models. Also, the push-to -talk assembly features a front-mounted button for easy use inside HazMat suits, and a lapel mic for use without a facepiece.
MSA EXTENDAIRE II SYSTEM UPGRADE
MSA's ExtendAire Systems are Emergency Breathing Supply System (EBSS) accessories that use intermediate pressure air to provide firefighters with a source of emergency breathing air. The ExtendAire system allows firefighters to quickly and easily connect to and breathe from a fellow firefighter's air cylinder. ExtendAire Systems are tightly integrated with the SCBA to provide unrestricted mobility and easy access during critical situations. The system uses a quick connect with an integrated check valve that prevents the breathing air pathway from being contaminated by ambient air. MSA's new ExtendAire II System offers an integrated rescue hose used with the PR14' First-Stage Regulator that features both male and female quick-connect fittings. The system is stowed in a waist pouch that mounts on the carrier assembly and is designed to prevent snagging and accidental opening. The ExtendAire II System also connects to the ExtendAire I System for additional system flexibility.
MSA G1 5500 SCBA
MSA’s tried-and-trusted G1 SCBA now comes available in a 5500 psig operating system. Their lowest profile, most comfortable, streamlined and balanced SCBA can now be configured with the lightest weight cylinders on the market today, reducing stress and fatigue while increasing maneuverability in confined spaces.
MSA G1 RESCUEAIRE II PORTABLE AIR-SUPPLY SYSTEM
The MSA G1 RescueAire II System for Rapid Intervention Teams (RITs) provides firefighters with emergency breathing air, including air supply to trapped firefighters wearing SCBA with compatible system(s). Built for extreme fire service conditions, the G1 RescueAire II System offers two operating pressures, 2216 and 4500 psi. Optional-use shoulder strap provides hands-free carrying. System incorporates G1 Regulator; RIT teams can provide air to downed firefighter wearing G1 Facepiece. G1 Regulator connects directly to G1 Facepiece for maximum rescue capability, supported by flame and heat-resistant carrying harness of Nomex and Kevlar materials.
MSA G1 RIT SYSTEM
The MSA G1 RIT System has everything needed for RIT response. Internal pneumatics includes a G1 RIT System quick-connect pressure reducer that mounts directly onto user-supplied SCBA cylinder.
MSA G1 SCBA
The MSA G1 SCBA is designed with technology to drive firefighting into the future. Bluetooth, RFID, Near Field Communications(NFC), and long-range radio capabilities allow for fast and easy integration of current and future technologies. The MSA G1 is the first SCBA with a Rechargeable Battery, Motorola Radio Bluetooth Connection, and their latest advancement, the MSA G1 with Integrated TIC.
MSA G1 SCBA BATTERY
CHANGE IS GOOD - UNLESS IT COMES TO BATTERIES
There is a new way to deal with replacing SCBA Alkaline batteries - DON'T. Introducing the first NIOSH approved and NFPA compliant SCBA platform to provide a rechargeable battery.
MSA G1 SCBA BATTERY SMART CHARGER
CHANGE IS GOOD - UNLESS IT COMES TO BATTERIES
There is a new way to deal with replacing SCBA Alkaline batteries - DON'T. Introducing the first NIOSH approved and NFPA compliant SCBA platform to provide a rechargeable battery Smart Charger.
MSA G1 SCBA INTEGRATED THERMAL IMAGING CAMERA
NOW APPROVED AND SHIPPING!
The MSA G1 SCBA Integrated Thermal Imaging Camera provides EVERY firefighter the ability to see in dark and smoke filled environments, aiding in the speed and effectiveness of your operation from the initial 360, to working the fire, overhaul and rescue. This sight is provided through a Thermal Imaging Camera that is integrated into the G1 SCBA Control Module, eliminating the need to carry an addition piece of bulky equipment and the concern of an additional snag hazard.
MSA RESCUEAIRE II PORTABLE AIR-SUPPLY SYSTEM
MSA's RescueAire II Portable Air-Supply System provides easy-to-use, portable, and compact emergency breathing air. Designed for Rapid Intervention Teams (RITs), whose missions are to rescue downed first responders and others requiring assistance, the RescueAire II System is a lightweight and rapid solution for your team. The RescueAire II Portable Air-Supply System is compatible with all of your FireHawk MMR Air Masks, which also include the FireHawk M7 Air Mask. This feature-packed system consists of flame-and heat-resistant carrying harness with adjustable Nomex/Kevlar shoulder strap, Audi-Larm Audible Alarm low-pressure warning device, pressure-reducing regulator, second-stage mask-mounted regulator, 36" Quick-Fill System EBS connection, and ExtendAire System EBS connection. RescueAire II Portable Air-Supply System is available in both low-pressure (2216 psig) and high-pressure (4500 psig) versions. An optional-use shoulder strap is also provided for hands-free carrying.